Armada Technologies Pro-48K TechTool Solenoid Activator Kit Made By Armada Technologies - Irrigation Testing and Locating Equipment
Armada Technologies Pro-48K TechTool Solenoid Activator Kit Made By Armada Technologies - Irrigation Testing and Locating Equipment

Armada Technologies Pro-48K TechTool Solenoid Activator Kit

The Pro-48K TechTool Solenoid/Clock Checker Kit is the must have basic tester for irrigation professionals. Included in the kit is a model Pro48 Solenoid / Clock Checker, a Pro200 Probe, a Pro21 Case, and a User Guide.

  • Currently 3/5
  • 1
  • 2
  • 3
  • 4
  • 5

Rating: 3 out of 5 (18 votes cast)

Click here to write a review

Armada Technologies - Irrigation Testing and Locating Equipment
Model List Price Your Price Quantity
4 Piece
Pro-48K

More Infoshippingcostemailreviews
$139.00 $139.00
Have you seen it lower?

More Details:

Armada Technologies Pro-48K TechTool for Professional Irrigation Contractor

The Pro-48K TechTool - Solenoid/Clock Checker Kit
Must have basic tester for irrigation professionals. Included in the kit is a model Pro-48 Solenoid/Clock Checker, a Pro200 Probe, a Pro21 Case, and a User Guide.

  • Chatters, yes Chatters, Solenoids!
  • Activates and Holds Solenoids Open.
  • Generates and Traces 1Khz Tracing Tone.
  • Checks Clock 24v Power Output.
  • Tests for Open or Shorted Wiring.
  • Uses 2 9v Batteries (not included).

The Pro-48K TechTool Solenoid and Clock Checker Kit is a new low cost test set for irrigation contractors and maintenance personnel. The Pro48K performs a series of simple procedures to test, verify, and identify solenoid, wire, and clock problems. Solenoids can be checked using either activation or chatter modes. Lost or buried solenoids are quickly found as well by listening for the chatter. Wiring can be verified and tagged with the built in tone generator function. Clocks also are tested for proper 24v transmission with a simple LED power check.

Made from a grommited, thick walled plastic case, the highly visible yellow TechTool is designed for rugged use in the field.

Model Pro-48 TechTool
The Pro48 TechTool is a portable, battery operated irrigation system tester and solenoid activator. Its functions include:

  • Testing voltage/current from the clock
  • Activating solenoids
  • Testing solenoids for continuity
  • Chatter the solenoid –for location of valve Sending tone to identify wires

Chatter the solenoid valve NOTE: The GOOD LED must illuminate under the “Solenoid and Activate mode” before using the chatter mode.
1. To chatter the solenoid for the purpose of locating the valve from the clock, turn the clock off and switch the Pro48 to OFF mode.
2. TURN OFF WATER to irrigation system.
3. Disconnect both the station and common wire from the controller.
4. Connect the Pro48 by attaching the red lead to the station wire and the black lead to the common.
5. Select side switch to CHATTER and top Switch to SOLENOID mode.
6. Proceed to the field and listen for the chattering sound at the solenoid valve.

Sending Tone
1. To identify a single wire from a bundle of similar wires, attach the red lead to the station wire and the black lead to earth ground.
2. Switch to SEND TONE mode.
3. Proceed to opposite end of wire and trace the tone with any Pro200 Series inductive amplifier. Reception of tone and the red LED will be strongest and brightest on the subject wire.

Pro-48K Tech Irrigation Contractors Tool Specifications

Pro48K Tech IrrigationTool Specifications

Model Pro-48K (Pro48K)
Electrical Minimum Voltage for Clock LED 15 Vac
Minimum Battery while Testing 10.5 Vdc
Maximum Input Voltage Between Test Leads 28 Vac
Solenoid Circuit Recharge Time 2.5 sec
Peak output voltage 36 Vdc
Maximum distance range for one Solenoid (depending on battery condition):
12 AWG Loop 3000-13000 feet
14 AWG Loop 2000-8500 feet
18 AWG Loop 500-3000 feet
Physical Length 160 mm (6.0“)
Width 80 mm (3.0”)
Depth 35 mm (1.5”)
Weight 0.27 kg (9.6 oz)
Operating/Storage Conditions
Temperature:
Celsius 0° C to 50° C
Fahrenheit 32° F to 122° F

Maintenance / Cleaning

Maintenance:

Battery Replacement:
1. Turn the unit off.
2. Disconnect the unit from the circuit.
3. Remove the battery cover.
4. Replace the batteries (observe polarity).
5. Replace the battery cover.

Cleaning:

Periodically wipe with a damp cloth and mild detergent; do not use abrasives or solvents.

One-Year Limited Warranty

Pro-Tech Equipment warrants to the original purchaser of these goods for use that these products will be free from defects in workmanship and material for one year, excepting normal wear and abuse. For all test instrument repairs, you must first request a Return Authorization Number by contacting our Customer Service department at (480) 926-8324. This number must be clearly marked on the shipping label. Ship units Freight Prepaid to: Pro-Tech Equipment 39780 Rattle Snake Dr., Queen Creek, AZ 85242 Mark all packages: Attention: TEST INSTRUMENT REPAIR. For items not covered under warranty (such as dropped, abused, etc.) repair cost quote available upon request.

Note: Prior to returning any test instrument, please check to make sure batteries are fully charged.

Activating the Solenoid at the Clock

OPERATION:

Battery Test
1. Connect the leads together.
2. Switch to SOLENOID ACTIVATE mode.
3. If the batteries are good (at least 10.5 volts) the SHORT LED will turn on.

Clock Test
1. With the clock on and turned to the station under test, switch to OFF mode.
2. Connect the red lead to the station wire and the black lead to common.
3. If proper voltage/current is detected, the CLOCK 24V AC LED will turn on. Solenoid Activate & Test NOTE: The TechTool cannot activate solenoids that run on AC voltage only. (For example, capacitor coupled solenoids)

Activating solenoid at the clock
1. To activate solenoids from the clock, turn the clock off and switch the Pro48 to OFF mode.
2. Connect the Pro48 by attaching the red lead to the station wire and the black lead to the common.
3. Switch to SOLENOID mode and select side switch to ACTIVATE.
4. The solenoid under test should activate and the GOOD LED (see display on the front of the Pro48) should turn on. If the solenoid does not activate, one of the following conditions may exist:

  • Possible Short: SHORT LED is on (< 10 Ohm)
  • Possible Open: OPEN LED is on (> 200 Ohm)

5. The Pro48 must be switched to the OFF mode to reset the unit after the solenoid is activated. NOTE: If the GOOD LED does not illuminate, the solenoid should be tested at the valve.

  1. Turn the clock off and switch the Pro48 to OFF mode.
  2. At the valve, attach the red lead to the station wire and the black lead to common.
  3. Switch to SOLENOID mode and select side switch to ACTIVATE.
  4. The solenoid should activate and the GOOD LED (see display on front of unit) should turn on. If the solenoid does not activate, one of the following conditions may exist:
    • Possible Short: SHORT LED is on (< 10 Ohm)
    • Possible Open: OPEN LED is on (> 200 Ohm)

NOTE: If the GOOD LED is on and the solenoid does not activate, it may be due to a mechanical failure in the valve.

  • Last Updated: 8/2/2008 12:15:55 PM
  • Store ID: 151058
  • Back to Top
Additional Images:
Related Items:
Related Categories:
Product Reviews:

There are currently no customer reviews for this product. Be the first to add one by filling out the form below!




Add a Review
Name:
( public & required)
E-mail:
( not public & required)
Where are you from?:
( public & optional)
Review:
 

Our Acceptable Review Guidelines

Before being posted, we look over all reviews to make sure they follow our guidelines. If your review isn't accepted because it fails to follow our acceptable review guidelines, you will receive an e-mail with the reason the review was rejected. You are welcome to edit your review at any time, and if a review is rejected you may modify it to comply with our acceptable review guidelines.

  • Please refrain from use of offensive, or abusive language, derogatory statements, or swearing.
  • Your review must have a direct bearing on the item being reviewed.
  • Please refrain from mentioning costs, as our prices are subject to rapid change.
  • If you have negative comments or criticism about AccentShopping.com or any of our business partners, such as UPS, please use the appropriate 'contact' method. A product review is an inappropriate place to initiate such a dialogue.
  • Please refrain from referring to other stores, wholesellers, or resellers.
  • Please do not include URLs in your review.
  • We reserve the right to deny any review on any terms, whether they are covered above or not.
Back to Top

Suggestions:

If you have discovered a typo, incorrect information, or encountered a technical issue on this page, we want to hear about it. Your opinion is important to us.

Please only leave your comments in the box below. If you have an inquiry you would like to make or you need to contact us, please click here.

How can we make our website better for you?

cast your vote!
Getting Results. Please wait....


Shipping & Returns Find a Product Customer Service Site Help
BizRate Customer Certified (GOLD) Site NexTag Seller