Honeywell S8610U3009 Universal Replacement Intermittent Pilot Module
One or Two Rod Intermittent Pilot Control with continuous retry trial time with configurable lockout timing of 15 or 90 seconds and configurable prepurge of 30 seconds or no prepurge
| Model | List Price | Your Price | Quantity |
|
Universal Replacement Intermittent Pilot Ignition Module SKU: S8610U3009 |
$158.03 | $126.42 |
Honeywell S8610U3009 Universal Replacement Intermittent Pilot Module
Overview of the Honeywell S8610U3009 Universal Replacement Intermittent Pilot Module :
Field service replacement for most Honeywell, Robertshaw, Johnson Controls, and UTEC (HSC) Intermittent Pilot Ignition Modules. Provides electronic control of most intermittent pilot ignition systems used on gas-fired furnaces, boilers, and other heating appliances.
Great new features make the Honeywell S8610U an even smarter choice. With the addition of field-selectable prepurge and ignition trial timings, the S8610U offers universal replacement compatibility for more than 300 Honeywell and competitive models. The S8610U also now boasts an LED flame strength indicator and a diagnostic LED that helps direct service efforts. Suitable for use with vent dampers, the upgraded S8610U provides electronic control for nearly any intermittent pilot ignition systems used on gas-fired furnaces, boilers and more. The Honeywell S8610U works in single-rod and dual-rod applications and works with both natural and LP gas. In short, for new installations or field replacement of nearly every Honeywell and competitive model, the S8610U is the only intermittent pilot ignition control you need.
For 100% pilot gas shutoff, the S8610U is the 100% choice. It provides the ignition sequence, flame monitoring and 100% safety shutoff. For intermittent pilot central furnaces and heating appliances, the S8610U is the only control you need.
New Enhanced Features:
Everything that’s made the S8610U so popular is still there, along with some additions that make the S6810U even better. Get easy field replacement of more models than even with field-selectable prepurge and ignition trial timings. An LED flame strength indicator and a diagnostic LED help speed up installation and service. Plus, the S8610U is now suitable for use with vent dampers. With universal compatibility and a wide range of great features, the S8610U is more flexible than ever.
Built-In Safety:
The S8610U is built for safety for you and your customers. It provides 100% pilot gas shutoff if the pilot fails to light, with a 90-second maximum lockout for added safety. After a sixminute delay, trial for ignition is repeated. This multi-trial ignition sequence continues until the appliance lights or the call for heat
has been removed, helping to eliminate nuisance callbacks.
Universal Compatibility:
Stock it, grab it, install it. The S8610U offers such universal compatibility that it’s the only intermittent pilot ignition control you need to stock. It replaces more than 300 Honeywell and competitive models, so whether you’re working on single-rod or dual-rod applications, dealing with natural or LP gas appliances
or replacing a control from Honeywell or another brand, you can reach for the S8610U and know you’ve got the situation handled. Honeywell also helps speed up the field replacement process by including spark cable adapters that allow replacement of Honeywell and competitive controls without the need to replace existing spark cables.
Proven Reliability:
With more than a decade of service in the field, the S8610U is time tested and proven. You can replace more than 300 competitive models with the S8610U and know that Honeywell’s long history of quality and reliable service is working for you.
Honeywell S8610U3009 Features & Specifications
Honeywell S8610U3009 Features:
- Provides ignition sequence, flame monitoring and safety shutoff for intermittent pilot central furnaces and heating appliances.
- Provides 100 percent pilot gas shutoff if pilot fails to light; after 6-minute delay, trial for ignition is repeated. Ignition trial/delay sequence is repeated until the appliance lights or call for heat is removed.
- For use with Natural or LP gas.
- For use in single rod or dual rod/remote sense applications. Includes relay contacts for use with any intermittent pilot gas control string with maximum 1.0A pilot or 2.0A main valve rating; Honeywell VR8204, VR8304 or VR8345M combination gas control recommended.
- Functional equivalent of S86, S8600, S8610 and S90 modules.
- Includes spark cable adapters to allow field replacement of both Honeywell and competitive controls without replacing existing spark cable.
- Vent damper connection with automatic vent damper plug; makes for easy replacement for appliances with or without a vent damper.
- EnviraCOM communications for additional diagnostics
Honeywell S8610U3009 Specifications:
- Description ----- One or Two Rod Intermittent Pilot Control with continuous retry trial time with configurable lockout timing of 15 or 90 seconds and configurable prepurge of 30 seconds or no prepurge
- Ignition System Type ----- Intermittent Pilot
- Ignition Sequence ----- Continous retry, after trial for ignition, pilot gas shuts off for 5 minutes, then another trial for pilot ignition takes place
- Typical Gas Control ----- VR8204, VR8304
- Type of Gas ----- Natural or LP
- Flame Sense ----- Single Rod or Two Rods
- Ignition Source ----- Internal high voltage spark generator
- PrePurge ----- Configurable to 30 seconds or no prepurge
- Ignition Trials To Lockout ----- Continuous retry
- Lockout Timing ----- Configurable to 15 seconds or 90 seconds
- Ignition Trial Time (sec) ----- Continuous retry
- Maximum Valve Load @ 24 Vac (Amps) ----- 1A Pilot, 2A Main @ 165 F; 1A Pilot, 1A Main @ 175 F
- Typical Ignition Hardware ----- Q345, Q3451, Q3452
- Dimensions (in.):
- Height ----- 3 15/16 in. (100 mm)
- Width ----- 5 7/16 in. (138 mm)
- Depth ----- 2 5/8 in. (67 mm)
- Electrical Ratings:
- Voltage ----- 24V, 60 Hz
- Current Draw ----- 1A pilot valve, 2A main valve
- Valve Contact Rating ----- 0.2A
- Frequency ----- 50/60 Hz
- Maximum Ambient Temperature (F) ----- -40 F to +165 F
- Maximum Ambient Temperature (C) ----- -40 C to +74 C
- Approvals, Canadian Standards Association ----- Design Certified
- Includes ----- Damper connection with automatic vent damper plug
- Tradeline Value ----- Super Tradeline
- Between Trial Time (sec) ----- 5 minute delay after failed trial for ignition.
- Flame Failure Response Time (sec) ----- 2 seconds maximum
Honeywell S8610U3009 Replacement Information
Honeywell S8610U3009 Replacement Information:
- Honeywell:
- S86
- S90
- S8600
- S8610
- S8660
- S8670
- Penn-Johnson:
- CSA
- G60-76
- G600
- G670
- G770
- Robertshaw:
- 780
- SP715 / SP735
- Fenwal:
- 05-20
Honeywell S8610U3009 Additional Docmumentation:
Sell Sheet
Installation Instructions
Quick Reference Guide
Product Data Sheet
White Papers
- Last Updated: 5/20/2008 10:29:43 AM
- Store ID: 154024
- Back to Top
There are currently no customer reviews for this product. Be the first to add one by filling out the form below!
Please only leave your comments in the box below. If you have an inquiry you would like to make or you need to contact us, please click here.